An RCD Test Log is a written record of mandatory safety checks performed on Residual Current Devices. Under the Work Health and Safety Act 2011 and AS/NZS 3760, Australian businesses must test RCDs regularly and log results to ensure electrical safety in the workplace.

A record used to track the testing of Residual Current Devices to ensure they work correctly and meet Australian safety standards.

Use Free Template
Create your custom version — free to start

20 free credits on signup — no card needed

spreadsheet
moderate
high Risk

About this Document

An RCD Test Log is an essential record for any Australian business or tradesperson who uses portable electrical equipment or operates construction sites. This document serves as proof that you have tested your Residual Current Devices, also known as safety switches, to ensure they operate correctly. RCDs save lives by switching off electricity quickly if a fault occurs. However, like any mechanical device, they can fail. Testing them regularly and recording the results is not just a good idea. It is a legal requirement under Australian workplace health and safety laws. This guide explains what an RCD Test Log is, when you need to use it, and how to fill it out correctly. We cover the specific legal requirements in Australia, including the Work Health and Safety Act 2011 and the relevant standards like AS/NZS 3760 and AS/NZS 3012. We also explain the difference between a push button test and a time current test. We provide clear steps to help you stay compliant and keep your workplace safe. An RCD is a safety device designed to prevent electric shock. It monitors the flow of electricity through a circuit. If it detects a leak of current to earth, it shuts off the power immediately. This prevents serious injury or death. There are two main types of RCDs used in workplaces. Fixed RCDs are installed in switchboards. Portable RCDs are used with portable equipment. Both types need regular testing. The RCD Test Log is the place where you write down the date of the test, the result, and the name of the person who did the test. Under the Work Health and Safety Act 2011, a Person Conducting a Business or Undertaking or PCBU must ensure that electrical equipment is safe to use. This includes RCDs. The model Code of Practice for Managing Electrical Risks in the Workplace states that RCDs must be tested regularly. The frequency of testing depends on the type of environment. For construction sites, the rules are stricter. For offices, the interval might be longer. You must follow the AS/NZS 3760 standard for in-service safety inspection and testing of electrical equipment. This standard sets out the testing intervals and methods. If you work on a construction site, you must follow AS/NZS 3012. This standard requires RCDs to be tested daily for portable devices and monthly for fixed devices. Keeping an accurate log is your defence if an inspector visits your site. It shows you are proactive about safety. If an incident occurs, the log is evidence that you did everything reasonable to manage the risk. Failure to keep a log can lead to heavy fines. Penalties for breaching the WHS Act can run into hundreds of thousands of dollars for corporations. Individuals can also face personal fines. It is simply not worth the risk. To complete an RCD Test Log, you need the right equipment. You must use a portable RCD tester. This device simulates an earth fault and measures the time it takes for the RCD to trip. You cannot rely on the test button on the RCD alone. The test button only checks the mechanics, not the timing. Your log should capture specific data points. You need to record the ID number or location of the RCD. You need the date of the test. You need the operating time in milliseconds. Most importantly, you need to record if the device passed or failed. If an RCD fails, you must tag it Do Not Use and remove it from service immediately. You must then repair or replace it before it goes back into use. Record this action in your log as well. Common mistakes include relying only on the test button and forgetting to sign the log. Another mistake is testing RCDs that are not connected to the actual load they are protecting. You should always test the RCD while it is connected to the circuit it protects. You should also test both the active and neutral poles if required by the standard. Small business owners often think these rules only apply to big companies. This is wrong. The law applies to all businesses. If you employ a tradesperson or an apprentice, you are a PCBU. You have a duty of care. If you are a sole trader working for yourself, you still have a duty to ensure your own safety. This means you should still test and log your RCDs. The log can be a paper book or a digital file. It must be available for inspection. Safe Work Australia inspectors can ask to see your records at any time. If you cannot produce them, you may be fined. The log must be kept for the life of the equipment or for a specific period as required by your jurisdiction. Some states require records to be kept for up to seven years. You should check with your local WHS regulator. In summary, the RCD Test Log is a critical safety document. It protects lives and protects your business. It is easy to maintain but often overlooked. Make it a habit to test and record. Train your staff to do it correctly. Integrate it into your start up and shut down procedures. This guide has covered the legal basis, the practical steps, and the common errors. By following this advice, you will meet your obligations under the Fair Work Act 2009 regarding workplace safety and the WHS Act 2011. You will also comply with the Australian Standards. Do not wait for an accident to happen. Start your RCD Test Log today. Ensure your tester is calibrated. Ensure your staff are competent. A competent person is someone who has the right knowledge, skills, and experience. They might need formal training. You should provide this training. Keep your records organized. If you have multiple sites, keep a separate log for each site. If you have many RCDs, use a numbering system to identify them. This makes the testing process faster and your records clearer. Remember that electrical safety is not optional. It is a fundamental requirement of doing business in Australia. Your RCD Test Log is the proof that you take this responsibility seriously.

Key Facts

  • RCDs must be tested by a competent person using a calibrated portable appliance tester that can measure trip time.AS/NZS 3760:2022
  • PCBUs must ensure electrical equipment is safe, which includes maintaining RCD testing records.Work Health and Safety Act 2011 (Cth)
  • Portable RCDs on construction sites require a push-button test before each use.AS/NZS 3012:2019
  • Fixed RCDs in workplaces must be tested for operating time at least every six months.Code of Practice: Managing Electrical Risks
  • Failure to maintain test records can result in fines of up to $50,000 for individuals and higher for bodies corporate.Safe Work Australia
  • The test button on an RCD unit only checks the mechanism, not the trip time or sensitivity.Electrical Safety Regulators

Sources

Required Sections

Header Information

Identifies the business, site, and compliance standard used for testing.

Header Information

Business Name Enter the full legal name of your electrical contracting business or trading entity. This field identifies the responsible party for the testing work performed. You must ensure the business name matches the details on your electrical licence and insurance policies. Under the Work Health and Safety Act (or Occupational Health and Safety Act in Victoria), the person conducting a business or undertaking (PCBU) holds the primary duty of care to ensure electrical equipment is safe. Recording your business name clearly establishes accountability. If you operate as a sole trader, write your own name.

Australian Business Number (ABN) Record your 11-digit Australian Business Number. Inclusion of the ABN is standard practice for commercial records and tax purposes. It distinguishes your business entity from others and ensures the documentation is valid for client invoicing and compliance audits. Clients often require this number to verify that the service provider is a registered entity for GST purposes. Ensure the number is current and active on the Australian Business Register.

Site Address Provide the full physical street address where the testing took place. Do not use a postal address or PO Box. This location pinpoints where the residual current devices (RCDs) are installed and operating. Specific location details are vital for compliance records. If an electrical safety incident occurs later, authorities such as Safe Work Australia or the state energy regulator will use this address to investigate the history of the installation. For large multi-unit complexes, include the specific unit number or lot number. If the work is performed at a mine site, you must record the specific mine location and the name of the mine operator as required by the Work Health and Safety (Mines) Regulations.

Australian Standard Specify the exact Australian Standard used to conduct the testing and verification. For regular testing and tagging of RCDs, the relevant standard is typically AS/NZS 3760:2022 (In-service safety inspection and testing of electrical equipment). If you are verifying a new installation or switchboard upgrade, you must reference AS/NZS 3000:2018 (Wiring Rules). Stating the correct standard is non-negotiable. It defines the test methods, pass/fail criteria, and the maximum trip times you must measure. Without citing the standard, your test results have no legal standing or technical basis. Ensure you reference the most current version adopted by your state or territory electrical regulator.

Required

Testing Record Table

The main data grid for recording specific test results for each device.

DateRCD IDDevice TypeTest TypeOperating TimeResultTester Name

Using this table correctly is vital for meeting your legal duty of care. Under the Work Health and Safety Act (WHS Act), you must ensure electrical equipment is safe. This includes residual current devices (RCDs) or safety switches. Keeping a log like this provides the proof regulators need during an audit or after an incident.

The tests recorded here must follow the AS/NZS 3760:2022 standard. This is the benchmark for the in-service safety inspection and testing of electrical equipment. You must perform a push-button test every six months to confirm the mechanical mechanism works. You must also conduct an operating time test using a precise meter at least every 12 months. This timing test checks that the device trips fast enough to prevent a fatal electric shock.

For general areas, Australian regulations require the RCD to trip within 300 milliseconds. For specific high-risk environments like wet areas or construction sites, the requirement is tighter at 40 milliseconds. Record your exact reading in the Operating Time column. A reading under these limits is a Pass. A reading over the limit, or a failure to trip at all, is a Fail. Any RCD that fails must be tagged out and repaired or replaced immediately.

You must record the Date and RCD ID for every test. The RCD ID helps you track specific units if you have multiple boards on site. The Device Type column should note if it is a portable RCD unit or a fixed switchboard device. The Tester Name confirms who conducted the safety check. This is important for accountability.

Keep these records for at least five years. Inspectors from Safe Work Australia or state WHS regulators can ask for them at any time. Gaps in your log suggest negligence and can result in significant fines. If you run a small business, you can rely on a competent person to do this testing. You do not always need a licensed electrician for the push-button test, but you do need one for the timing test. Ensure whoever fills out this table is qualified and understands the requirements of AS/NZS 3760:2022.

Required

Failure and Remedial Actions

Details what to do if an RCD fails the safety test.

If an RCD fails a push-button test or an operating time test, you must stop using the protected circuit immediately. Record the failure in the RCD Test Log as soon as the fault is identified. Write the word 'FAIL' clearly in the test result column for the relevant date and include the specific nature of the fault. For example, note if the device failed to trip or if the operating time exceeded the limits set out in AS/NZS 3760.

Attach a durable 'Danger Do Not Use' tag to the RCD or the switchboard to prevent accidental use. This tag acts as a clear warning to others that the safety device is non-functional. If the RCD protects a specific item of portable equipment, tag the equipment itself as well. Under the Work Health and Safety (WHS) Regulations, you must isolate the equipment or circuit from the electrical supply to eliminate the risk of electric shock.

Do not restore power until you complete the necessary remedial actions. You must either repair the faulty RCD or replace it with a new unit that meets current Australian Standards. If you repair the device, ensure the repair work is carried out by a licensed electrician. Record the full details of the remedial action in the log. Include the date of the repair or replacement, the name of the person or company who performed the work, and a description of the work done. If you replaced the RCD, record the make, model, and serial number of the new device.

After completing the repair or replacement, you must retest the RCD to verify it operates correctly. Perform both the push-button test and the operating time test according to AS/NZS 3760. Record the new test results in the log to confirm the device now complies with the standard. This documentation creates a clear audit trail demonstrating that you have managed the electrical risk in accordance with the WHS Act. Retain these records for the duration of the equipment's life or as required by your specific workplace regulations.

Required

Tester Sign Off

Authorization section for the person responsible for the testing.

Tester Sign Off

Tester Name:

Signature:

Date:

Why this section matters

The tester sign off is the final step in the testing and tagging process. By signing this document, you are legally declaring that the testing work has been carried out correctly and the RCD log is a true and accurate record. In Australia, workplace safety legislation places a strong emphasis on the responsibility of the person conducting the business or undertaking (PCBU) and the competent person performing the testing. Your signature is your confirmation that you meet the standard of a "competent person" as defined in AS/NZS 3760:2022.

You must print your full name clearly alongside your signature. This ensures there is no confusion regarding who performed the work. If an inspection occurs or an incident happens later, Work Health and Safety (WHS) regulators, such as Safe Work Australia or state-based SafeWork bodies, will look to this log to identify who verified the safety of the electrical equipment. If your handwriting is illegible, it may cause complications during an audit.

The date is critical for compliance scheduling. It marks the end of the current testing period and starts the clock for the next re-test date. Under the model WHS Regulations, you must maintain these records. AS/NZS 3760:2022 specifies that you must keep records of testing for the duration specified in the standard, which is often up to seven years depending on the type of workplace and equipment. Your sign off finalises the record for that period.

Legal and Professional Obligations

When you sign, you are verifying that the RCD tests were performed in accordance with the manufacturer's instructions and relevant Australian standards. Specifically, this refers to the requirements for push-button testing and operating time verification. You confirm that the RCD tripped within the time limits required for the specific installation environment, such as the general trip times for socket outlets or the requirements for specific equipment.

Providing false or misleading information in this log is a serious offence. It undermines the safety of the workplace and can lead to significant penalties under the WHS Act in your state or territory. If you did not personally conduct the tests or witness the results, do not sign the document. Only the individual who carried out the work should sign to certify its accuracy.

Checklist before signing

  • Ensure all test results are recorded clearly in the log.
  • Confirm that any failed RCDs have been tagged for withdrawal from service and repaired or replaced.
  • Verify that your name and the date are written legibly.
  • Keep a copy of this signed log for your own business records.
  • Provide the property owner or manager with the completed log.

This sign off is not just a formality. It is a formal declaration of safety compliance. Take it seriously to protect the lives of workers and the integrity of your business.

Required

Optional Sections

Asset Register

A list of all RCDs within the workplace to ensure none are missed.

The Asset Register is the central record for every Residual Current Device used in your business. You must list every portable RCD, fixed RCD, and socket-outlet RCD here. This register is not just for internal tracking. It is a legal requirement under the Work Health and Safety Regulation. An inspector can ask to see this list at any time to verify you are maintaining your safety equipment.

You must keep this register up to date. If you buy a new device, add it immediately. If you sell, lose, or destroy a device, remove it. Accurate records ensure you know exactly what equipment needs testing and when.

The columns below capture the essential data.

Asset Register

  • Asset ID Assign a unique code to every device. Do not rely on the serial number alone. Serial numbers are often long and difficult to read on small devices. Use a simple system like RCD-001, RCD-002, and so on. Place a sticker with this ID on the device casing. This makes it easy to link the physical device to your testing logbook and inspection tags.

  • Serial Number Record the serial number exactly as it appears on the device manufacturer plate. This number is the definitive proof of identity for the unit. It distinguishes your device from others of the same make and model. If the device does not have a serial number, write N/A and use the Asset ID as the primary tracker.

  • Make Write the brand name of the manufacturer. Examples include HPM, Clipsal, Schneider Electric, or Testech. This detail is important when ordering replacement parts or contacting technical support. It also helps when checking recall notices from manufacturers.

  • Model Record the specific model number. This tells you the technical specifications of the device. It confirms the operating current sensitivity, usually 10mA or 30mA. It also indicates if the device is a portable RCD or a powerboard with RCD protection. Always check that the model meets the requirements of AS/NZS 3760.

  • Current Rating State the ampere rating of the device. Most portable RCDs used by tradespeople are rated at 10A or 15A. You must ensure the RCD rating matches or exceeds the current draw of the equipment plugged into it.

  • Type Specify the type of RCD. Options include Portable, Portable Outlet Device, Fixed, or Cord Set. This classification helps you determine the correct testing interval under AS/NZS 3760. For example, portable equipment used on construction sites requires testing every 3 months, while equipment in a commercial office environment might only require testing every 12 months.

  • Location / Status Note where the device is kept or used. Is it stored in the main workshop, assigned to a specific ute, or installed in a specific switchboard? Also record the current status. Use terms like In Service, In Repair, or Written Off.

This register forms the basis of your safety maintenance system. By keeping these details accurate, you ensure your testing schedule is valid and your business remains compliant.

Optional

Frequently Asked Questions

What is an RCD Test Log?
An RCD Test Log is a formal record used to document the safety testing of Residual Current Devices. It proves that regular checks have been performed to ensure the safety switches function correctly.
When do I need an RCD Test Log?
You need an RCD Test Log whenever your business uses electrical equipment or operates in a workplace where an RCD is required. This includes construction sites, workshops, and offices.
Is an RCD Test Log legally required in Australia?
Yes, maintaining records of electrical safety testing is a requirement under the Work Health and Safety Act 2011. Safe Work Australia inspectors can request to see these logs during site visits.
How often must I test RCDs?
Fixed RCDs in workplaces typically need a time current test every six months. Portable RCDs used on construction sites need a push button test daily and a time current test every month.
Can I test an RCD myself?
You can test the push button function yourself. However, measuring the operating time usually requires a calibrated portable appliance tester and a competent person who understands the requirements of AS/NZS 3760.
What happens if an RCD fails the test?
If an RCD fails, you must immediately remove it from service and tag it 'Do Not Use'. You must record the failure in the log and repair or replace the device before using it again.
What information must be in the log?
The log must include the date of the test, the RCD ID or location, the type of test performed, the operating time, the pass or fail result, and the name of the person who did the test.
How long must I keep the RCD Test Log?
You should keep the log for as long as the equipment is in use at that workplace. Some workplace safety regulators recommend keeping records for up to seven years to cover potential liability claims.