An Electrical Test and Tag Log is a formal record of safety inspections and tests on portable electrical appliances. It is required by Australian WHS laws and AS/NZS 3760 to prove a business manages electrical risks.

A record used to track the inspection and testing of portable electrical appliances to ensure workplace safety compliance.

Use Free Template
Create your custom version — free to start

20 free credits on signup — no card needed

spreadsheet
moderate
high Risk

About this Document

What Is a Electrical Test and Tag Log?

An Electrical Test and Tag Log is a formal record used to track the safety inspection and testing of portable electrical appliances in a workplace. In Australia, this document serves as proof that a business has met its work health and safety obligations regarding electrical equipment. It is essentially a register that lists every item tested, the results of those tests, and the details of the person who carried them out.

While you might see a physical tag attached to the lead of a power drill or a office computer, the log is the master record. The tag on the cord is just a quick visual reference for the user. The log contains the detailed data, such as earth continuity readings and insulation resistance results, which prove the equipment was actually tested correctly according to Australian Standards.

The log also acts as an asset management tool. It helps business owners keep track of when equipment is due for re-testing. This is vital because electrical safety is not a "set and forget" task. Different environments require different re-testing frequencies, and the log is the tool used to monitor these schedules. Without a current and accurate log, a business leaves itself open to significant legal and financial risks if an incident occurs.

When to Use This Document

You must use this document if you are a Person Conducting a Business or Undertaking (PCBU) or an employer in Australia. The law requires that electrical equipment be maintained to ensure it is safe. If you have workers, volunteers, or members of the public interacting with your electrical appliances, you need to demonstrate that you have taken reasonable steps to manage the risk.

Specifically, you need to use this log when:

  • Conducting Routine Inspections: Whenever a "competent person" inspects and tests an electrical appliance.
  • Introducing New Equipment: When new electrical items enter the workplace. While brand new equipment in original packaging may not need immediate testing, it must be inspected and logged before it enters service.
  • Repairing Equipment: If an appliance fails a test, is repaired, and then put back into service, this must be recorded in the log.
  • Disposing of Equipment: If a faulty item is thrown out or permanently removed from the workplace, the log must record this action to show it is no longer in circulation.

The requirement applies to almost every industry. An office environment needs a log just as much as a construction site, although the frequency of testing will differ. If you are hiring out equipment, you are legally required to test and tag it before every hire. The log is the only way to prove you did this.

Key Sections and Required Elements

To be compliant with AS/NZS 3760:2010 and Australian WHS regulations, your log needs specific sections. A simple checklist is often not enough. The following elements ensure you have a complete legal record.

Asset Register (Appliance Details)

This section identifies the specific equipment. You need to be able to distinguish one power board from another. This section should include:

  • Asset ID: A unique number or barcode for the item.
  • Appliance Description: What is it? (e.g., Angle Grinder, Desktop Computer).
  • Make and Model: The manufacturer and model number.
  • Serial Number: Useful for warranty and insurance tracking.
  • Location: Where the item is kept or used.

Risk Assessment & Environment Class

This is a critical section that determines how often you need to test the item. The level of risk changes depending on where the equipment is used. You must classify the environment in your log.

  • Environment Type: Is it an office, a factory, a workshop, or a construction site?
  • Class: The AS/NZS 3760:2010 standard assigns different intervals to different environments. For example, an office might be low risk (5 yearly), while a construction site is high risk (3 monthly).
  • Frequency: The log should explicitly state the required re-test date based on that classification.

Test Results & Integrity Checks

This is the technical core of the log. It records the actual data from the testing process. A simple "Pass" is not always enough for audit purposes. You should record:

  • Date of Test: When the check occurred.
  • Visual Inspection Result: Did the item look damaged? This is a mandatory step.
  • Earth Continuity: The reading in Ohms (for Class I equipment).
  • Insulation Resistance: The reading in Mega-Ohms.
  • Polarity Check: Passed or Failed (for extension leads).
  • Leakage Current: Result of the test.

Tag & Compliance Status

This section links the log to the physical tag on the appliance. It proves the testing was done by a qualified individual. Include:

  • Tag ID: The unique number on the physical tag attached to the cord.
  • Name of Tester: The full name of the competent person.
  • Tester Company: The business name of the technician or the internal department.
  • Next Test Date: The calculated date when the next inspection is due.

Defective Equipment Register

You must have a process for failed items. This section tracks what happens to equipment that is found unsafe. It should include:

  • Fault Description: Why did it fail?
  • Action Taken: Was it repaired, tagged out as "Danger: Do Not Use", or destroyed?
  • Disposal Authorisation: Who authorised the equipment to be thrown out? This prevents faulty gear from accidentally being put back in use.

How to Write a Electrical Test and Tag Log (Step by Step)

Creating and maintaining this log is a systematic process. Follow these steps to ensure your records hold up in an inspection or audit.

Step 1: Identify Your Equipment and Environment

Before you start testing, you need to know what you have and where it is used. Walk through your workplace and create an inventory. Assign a unique asset ID to every item. Determine the environment type for each area. An administrative area requires different testing intervals than a manufacturing floor. This classification will dictate the dates you enter later.

Step 2: Gather the Required Tools

Ensure the person performing the work is a "competent person". They must have the right training, such as a UEENEEP026A course, or be a licensed electrician. They will need a Portable Appliance Tester (PAT) and the appropriate physical tags. You can use a digital log system or a paper-based Register, but the data fields must remain the same.

Step 3: Perform the Visual Inspection

This is the first and most important step. The tester must look for obvious damage. Check the flexible cord for fraying, cuts, or exposed wires. Look at the plug for missing pins or cracked casing. Inspect the appliance itself for missing covers or visible damage. Record the result of this visual check in the log. If it fails visually, do not proceed to electrical testing. Tag it out immediately.

Step 4: Conduct Electrical Testing

For items that pass the visual check, connect the appliance to the Portable Appliance Tester. The tester will measure earth continuity, insulation resistance, and polarity. The machine will give a numerical reading or a Pass/Fail result. Record these specific values in the "Test Results" section of your log. Do not just record "Pass". Write down the actual numbers if possible, as this provides better evidence of compliance.

Step 5: Attach the Tag and Update the Log

Once the item passes, attach a durable, non-reusable tag to the cord. The tag must state the date of the test, the next due date, and the name of the tester or company. Now, enter the "Tag Details" into your log. Ensure the Tag ID in your log matches the physical tag on the cord. Calculate the "Next Test Date" based on the environment class you identified in Step 1.

Step 6: Handle Failures Separately

If an item fails the test, record it in the "Defective Equipment Register" section. Attach a "Danger - Do Not Use" tag to the item. Remove it from service immediately. If you send it for repair, keep a record of the repair and re-test it before it goes back into use. If you dispose of it, record the date and method of disposal in the log.

Common Mistakes to Avoid

Many Australian businesses get test and tag wrong simply because they cut corners or misunderstand the requirements. Avoiding these pitfalls will save you money and protect your workers.

Relying Solely on the Physical Tag

A common mistake is thinking the tag on the cord is your only record. It is not. Tags fall off, get torn, or fade in the sun. If an inspector visits and a tag is missing, the Test and Tag Log is your only legal defence. The log is the master record; the tag is just a label. Always keep the log up to date, even if the tag is still on the cord.

Using Incorrect Testing Intervals

Do not use a "one size fits all" approach. Testing office computers every 3 months is a waste of money and not required by law. Conversely, testing construction equipment every 12 months is a serious breach of safety standards. You must use the risk assessment section of your log to justify the frequency. Reference the tables in AS/NZS 3760:2010 to ensure you are testing at the correct intervals for your specific environment.

Skipping the Visual Inspection

Some testers plug the appliance straight into the machine without looking at it. This is dangerous. An electrical test can sometimes miss physical damage, such as a crack in the casing that exposes live parts. The visual inspection is mandatory. Your log must show that a visual check was performed and recorded separately from the electrical test.

Failing to Keep Records for Long Enough

You must keep your records. AS/NZS 3760:2010 requires you to keep the log until the equipment is next tested or disposed of. In reality, you should keep these records for at least 7 years to cover yourself for insurance audits and potential legal proceedings. Storing them digitally or using a cloud-based Compliance Tracker is a good way to ensure they are not lost.

Legal Considerations (AU)

Operating a business in Australia requires strict adherence to electrical safety laws. The consequences of non-compliance can be severe, including heavy fines and imprisonment.

Primary Duty of Care

Under the Work Health and Safety Act 2011 (Cth) and equivalent state legislation, a PCBU has a primary duty of care. This means you must ensure, so far as is reasonably practicable, that workers and others are not exposed to electrical risks. The Managing Electrical Risks in the Workplace Code of Practice explicitly references AS/NZS 3760:2010. Following this standard is the best way to demonstrate you are meeting your duty of care. Your Test and Tag Log is the primary evidence of this compliance.

State and Territory Variations

While the WHS Act is national, there are slight variations in how it is applied.

  • NSW, QLD, SA, TAS, ACT, NT: These jurisdictions follow the model WHS laws. The requirements are consistent with AS/NZS 3760:2010.
  • Victoria: Uses the Occupational Health and Safety Act 2004. While the Act is different, the duty to maintain safe plant is the same. Victoria generally refers to AS/NZS 3760:2010 as the benchmark for compliance.
  • Western Australia: Follows the Occupational Safety and Health Act 1984. Like Victoria, the general duty of care applies, and the standard is used to judge what is reasonably practicable.

The Competent Person Requirement

You cannot simply ask an apprentice to check the power boards unless they are trained. The law requires testing to be done by a "competent person". This is someone who has acquired the necessary knowledge and skills through training, qualification, or experience. Often this means a licensed electrician or someone who has completed a specific Test and Tag course. Your log must identify this person. If an untrained person fills out the log, the record may be invalid in a court of law.

Record Keeping and Inspectors

Safe Work Australia inspectors have the right to enter your workplace and ask for your safety records. If you cannot produce a Test and Tag Log upon request, you may face infringement notices. Furthermore, if an electrical accident occurs and you have no records, regulators will assume you have not maintained your equipment. The burden of proof is on you to show that you did everything reasonably practicable to ensure safety. The log is that proof.

Frequently Asked Questions (preview)

Do I need to test new equipment? According to the Code of Practice, new equipment that is still in its original packaging and has not been used does not require testing immediately. However, it must be visually inspected for damage. Once it is taken out of the packaging and used, it becomes "in-service" and the testing interval clock starts. You should record the purchase date and initial inspection in your log.

How long do I need to keep the logs? The standard requires you to keep the record until the equipment is tested again or disposed of. For business protection and insurance purposes, it is strongly recommended to retain these records for a minimum of 7 years.

Can I do the testing myself? Yes, provided you are a "competent person". You need to have the appropriate training to use the testing equipment and understand the results. Many business owners send a staff member to a TAFE or private training course to obtain the necessary qualifications, such as UEENEEP026A.

What is the tag colour coding system for construction? On construction sites in NSW, QLD, and other states, tags are colour-coded to correspond with the months of the year. This follows AS/NZS 3012:2010. For example, Red might be used for December to February, Blue for March to May, and so on. Your log should record the tag colour to make it easier to verify compliance visually on site.

Key Facts

  • The WHS Act 2011 imposes a primary duty of care on businesses to ensure electrical equipment is safe.WHS Act 2011 (Cth)
  • AS/NZS 3760:2022 sets out the intervals for testing and tagging electrical equipment.Standards Australia / New Zealand (AS/NZS 3760)
  • Construction sites require testing of portable electrical equipment every 3 months.Safe Work Australia Model Code of Practice
  • A competent person with relevant training must perform the testing and tagging.Safe Work Australia
  • Businesses must keep records for the duration of the asset's life and often longer for tax purposes.Australian Taxation Office (ATO)
  • Failed equipment must be immediately withdrawn from service and repaired or disposed of.WHS Regulations

Sources

Required Sections

Equipment Register

A list of all portable electrical appliances owned by the business.

Equipment Register

Asset IDItem DescriptionMake/ModelSerial NumberLocation
[ETT-001]240V Desktop ComputerDell OptiPlex 7090[DZ09212]Administration Office - Desk 4
[ETT-002]Electric KettleBreville Smart Kettle[BKE820XL]Staff Kitchen - Bench 1
[ETT-003]Corded DrillMakita HP457DWE[123456789]Maintenance Workshop - Shelf B
[ETT-004]Barcode ScannerZebra DS2200[ZDS2200-AU]Warehouse - Checkout Station 2
[ETT-005]Extension Lead4-Way Powerboard[PB-10M]Site Office - Floor Box 3
Required

Test Records

The specific details of each safety test performed.

Asset IDItem DescriptionLocationTest DateVisual InspectionElectrical TestNext Test DateTested By
ELP-001Honda 2400W GeneratorSite Shed A[DATE]Pass - No cord damagePass[DATE] + 6 Months[TECHNICIAN NAME]
ELP-002Makita Cordless Drill ChargerWorkshop Bench[DATE]Pass - Plug intactPass[DATE] + 12 Months[TECHNICIAN NAME]
ELP-003Extension Lead 10mSite Office[DATE]Fail - Frayed insulation exposedFail - N/AN/A[TECHNICIAN NAME]

Note: Items marked 'Fail' were immediately removed from service and labelled as dangerous. Testing conducted in accordance with AS/NZS 3760:2010.

Required

Failed Equipment Register

Record of items that failed testing and the actions taken.

Failed Equipment Register

Item IDEquipment DescriptionDate FailedDefect DetailsAction TakenTagged By
[TL-04][240V Angle Grinder][12/10/2023][Insulation resistance test showed reading below 1MΩ. Outer casing damaged near ventilation.][Immediately tagged "DO NOT USE" and removed from service. Sent to licensed electrician for repair assessment.][J. Smith]
[EXT-08][10m Extension Lead][12/10/2023][Visual inspection identified exposed copper wires on plug head and significant cuts on cord.][Cut plug end to prevent reuse and placed in e-waste bin. Replaced with new stock item #EXT-15.][J. Smith]
Required

Competent Person Details

Information about the person carrying out the tests.

Tester Name: [Full Name of Tester] Qualification: [Name of Course, e.g., Test and Tag Competency Course] Unit of Competency: UEENEEP026A Business/ABN: [Company Name] / [ABN Number] Phone Number: [04XX XXX XXX] Tester ID Number: [ID-12345]

Declaration: I declare that the testing and inspection detailed in this log were carried out in accordance with AS/NZS 3760:2010. I am a competent person with the necessary training and experience to operate the Portable Appliance Tester used for this inspection.


Signature of Competent Person

[Date of Signing]

Required

Business and Site Details

General information about the business and the specific site.

Business and Site Details

Testing Business Details: Trading Name: [Your Electrical Services] ABN: [12 345 678 901] Office Address: [123 Smith Street, Parramatta NSW 2150]

Client/Site Information: Client Name: [Apex Construction Group] Site Address: [456 George Street, Brisbane QLD 4000] Site Contact: [John Doe] Contact Phone: [0400 000 000]

Technician Details: Name: [Jane Smith] Qualification: [UEENEEP026A - Conduct in-service safety inspection of electrical cords] Tester ID: [TS-8821]

Required

Frequently Asked Questions

What is a Electrical Test and Tag Log?
An Electrical Test and Tag Log is a written record that tracks the safety testing of portable electrical appliances. It records what items were tested when they were tested and if they passed or failed the safety checks.
When do I need a Electrical Test and Tag Log?
You need this log whenever your business uses portable electrical equipment in the workplace. This is essential for complying with WHS laws and managing electrical safety risks effectively.
Is a Electrical Test and Tag Log legally required in Australia?
Yes specific record keeping is legally required under WHS Regulations to prove that you are managing electrical risks. While the format is not prescribed the law requires evidence that testing was done by a competent person.
How often do I need to test and tag equipment?
Testing intervals depend on the work environment. Construction sites require testing every 3 months while factories require 6 months and offices usually require 5 years. You should refer to AS/NZS 3760 for specific intervals.
Who can perform the testing and fill out the log?
Testing must be performed by a competent person. This usually means a licensed electrician or a qualified technician who has completed a specific test and tag training course.
What happens if an appliance fails the test?
If an appliance fails it must be immediately withdrawn from service to prevent injury. You must attach a 'Do Not Use' tag record the failure in your log and either repair it or dispose of it.
How long must I keep the Electrical Test and Tag Log?
You should keep the log for the entire life of the equipment. If the testing costs are tax deductions the ATO requires you to keep records for 5 years. It is best practice to keep records permanently.
What information must be included in the log?
The log must include the asset identification a description of the appliance the test date the next due date the name of the tester and the test result. It must also record the details of any failed items.

Explore More Process Documents

Ready to create your document?

Use our free template or generate a custom version tailored to your needs.

Use Free Template
Create your custom version — free to start

20 free credits on signup — no card needed

This document involves significant legal or financial considerations. Professional review is strongly recommended.

Last reviewed: July 30, 2026